Hand grip strength testing is most useful when another practitioner can repeat the same measurement and understand exactly how the score was obtained. Record the method as well as the number: device, handle setting, body position, hand, attempts and scoring rule.
This page provides a copyable grip-testing record, a standardisation checklist and a worked scoring example. For the measurement procedure itself, use our main grip-strength testing protocol alongside the instructions for your dynamometer and the reference method you have selected.
Agree the method before the first squeeze
There is more than one published grip-testing protocol. Roberts and colleagues’ review found substantial differences in equipment, positioning, attempts and the way results were summarised. These differences can affect comparisons.
Write down the procedure you intend to follow before testing. Avoid combining the posture from one protocol, trial count from another and a scoring rule chosen after seeing the results.
- Purpose: what decision will this assessment inform, and is maximal grip testing appropriate for the participant and setting?
- Reference: which protocol and, if needed, normative dataset will you use? Record its source and version.
- Device: which model, measurement range and handle setting are specified? Check the equipment as required by its instructions.
- Position: define sitting or standing, support, shoulder, elbow, forearm and wrist position.
- Trials: define familiarisation, hand order, number of attempts, contraction instructions and rest.
- Scoring: define whether the reported value is a hand-specific maximum, overall maximum, mean or another specified summary.
If pain, an injury or another limitation makes the planned test inappropriate, follow the relevant assessment procedure and seek the responsible practitioner’s guidance. Record why testing was changed or not completed; a blank is not a zero-strength result.
Copyable grip-strength testing record
Copy the fields below into your approved record system. Add or remove trial lines to match the selected protocol. The template does not prescribe a universal number of attempts or a clinical decision threshold.
Session and method
Participant reference and assessment date: [ ]
Assessor and assessment purpose: [ ]
Relevant screening/readiness record: [ ]
Protocol title, version and source: [ ]
Device manufacturer, model and asset ID: [ ]
Equipment-check reference: [ ]
Units displayed and recorded: [ ]
Handle setting and any permitted adjustment: [ ]
Body and upper-limb position/support: [ ]
Dominant hand, if collected: [ ]
Attempts
Familiarisation and standard instructions: [ ]
Planned hand order, trials and rest: [ ]
Trial number: [ ] Hand: [ ] Reading and units: [ ]
Valid trial? [yes/no; reason]
Rest, symptoms or deviations: [ ]
Additional trial records: [repeat these trial fields as required]
Score and interpretation
Scoring rule selected before testing: [ ]
Final value, hand(s) represented and units: [ ]
Reference dataset, age/sex group and applicable method: [ / no normative comparison]
Why the comparison is appropriate: [ ]
Previous comparable result and date: [ ]
Observed difference and relevant error evidence: [ ]
Limitations, explanation and agreed follow-up: [ ]
Keep the original trials even when a single summary score is reported. Link device checks to the equipment-check log; use the general assessment template when grip strength is part of a wider test session.
Worked example: the scoring rule changes the number
Illustrative readings only: assume a chosen protocol produced three valid readings per hand in the same units.
| Hand | Readings | Hand maximum | Hand mean |
|---|---|---|---|
| Left | 30, 31, 32 | 32 | 31 |
| Right | 31, 32, 33 | 33 | 32 |
The maximum across all six readings is 33; the mean of all six is 31.5. Both calculations are arithmetically correct, but they describe different summaries. Neither is automatically the correct reported score for every protocol.
Choose the summary required by the method and comparison dataset. Do not substitute a mean for norms based on a maximum, or change the rule at retest. Record the unit shown by the device; do not silently mix kg-labelled readings, pounds and newtons.
Keep the reference datasets separate
Our British grip-strength centile chart and grip-strength calculator use different reference sources. Read the source, age coverage, protocol and score definition on the resource you choose.
The Tomkinson international norms study harmonised data from different measurement methods. Its reference values are population comparisons, not an instruction to treat every dynamometer, posture or scoring rule as interchangeable. A low percentile alone does not diagnose a condition or determine fitness for work.
Before the next assessment
- Retrieve the previous protocol and raw trials, not just the final score.
- Match the device, handle setting, posture, hand order, trial count, rest, instructions and scoring rule as closely as the protocol requires.
- Record changes in equipment, preparation, symptoms or method.
- Report the observed difference separately from whether it exceeds relevant measurement error or is practically important.
- Choose the review date for the assessment purpose and recovery requirements; do not assume one retest interval suits everyone.
Use the retest plan and measurement-error guide when interpreting change. If suitable error evidence is unavailable, say so rather than assigning a universal percentage improvement.
Equipment and team workflow
Compare devices through the hand dynamometer buyer’s guide and check the specifications of the Takei Hand Grip Dynamometer. Select a model for the intended protocol and users; the display type alone does not establish its accuracy.
For help choosing equipment, discuss your testing setup. For broader digital assessment records and reporting, request Cartwright Assess details and confirm the functions currently available for your workflow.