Choose functional capacity evaluation equipment around the work tasks and measurements your service needs to assess. A portable set of instruments may cover selected measurements; a dedicated work-simulation system may support a broader protocol. Neither the equipment price nor the size of the kit establishes the quality of an FCE.
This guide helps with equipment selection. For assessment scope, reporting and the distinction between individual test results and work-capability recommendations, read our functional capacity evaluation guide. Clinical FCEs require appropriately qualified practitioners, a suitable protocol and an interpretation process.
Already have a protocol or equipment list? Discuss your setup and tell us what you need to measure, where you test and what equipment you already use.
Start with the assessment requirement
Write down the referral question and the relevant job demands before comparing products. Lifting a load, sustaining a posture, gripping a handle and completing an aerobic test are different tasks. A result from one should not be treated as a direct measure of all the others.
- Tasks: identify the movements, loads, working heights, distances, repetition and durations that matter.
- Protocol: specify the assessment method, participant suitability, supervision, stopping process and recording requirements.
- Measurements: identify the quantities, units, ranges and resolution the equipment must support.
- Setting: allow for access, clear floor space, stable surfaces, storage, cleaning and transport.
- People: confirm who will administer, interpret and report the assessment, and what training they need.
For professional context, the Chartered Society of Physiotherapy’s work and health resources cover work-related practice and support. Equipment selection is one part of establishing an assessment service.
Match equipment to the measurement
The table is a purchasing checklist, not a prescribed FCE battery. Include a component only when it fits the chosen assessment.
| Measurement or task | Equipment to consider | Confirm before ordering |
|---|---|---|
| Hand-grip force | Hand dynamometer | Handle adjustment, force units, range, calibration route and compatibility with the specified grip protocol and reference data. |
| Lifting and carrying | Protocol-specified loads, containers, shelves or work-simulation apparatus | Load verification, grip and shelf geometry, working heights, clear space and safe handling arrangements. |
| Pushing and pulling | Force gauge or a dedicated instrumented system | Force direction, attachment and mounting, measurement range and whether the method requires peak, sustained or repeated force. |
| Postural or task tolerance | Task-specific fixtures, seating, work surfaces and timing equipment | Repeatable positions, dimensions, timing and the observations required by the protocol. |
| Aerobic assessment, when indicated | Equipment specified by the selected step, cycle or treadmill protocol, with its required monitoring | Participant suitability, workload or pacing, monitor requirements, calculation method and operator training. |
| Balance, dexterity or other specific functions | A test-specific instrument or task setup | Evidence for the intended measurement, population and task; do not treat a balance score as a complete work-capacity assessment. |
Keep units explicit. For example, a device displaying kilograms-force (kgf) reports force, while kilograms (kg) describe mass. Record the actual device, settings and procedure so that later measurements can be compared appropriately.
Portable instruments or a dedicated system?
Portable instruments
A portable setup can be useful for selected assessments across several sites. Check the complete working arrangement: instrument protection during transport, suitable mounting, required accessories, local space and a consistent checking procedure. A small case does not automatically mean the whole protocol can be performed in any room.
Budget for staff time and records as well as the instrument. Manual entry, transfers between devices and changes in setup all need a documented procedure.
Dedicated work-simulation systems
A dedicated system can combine several measurements, attachments and reporting functions. Compare the exact configuration with the protocol you intend to use, including installation requirements, training, software licence, calibration, consumables and ongoing support.
For example, the manufacturer lists work-simulation attachments, several resistance modes, evaluation protocols and reporting functions for BTE PrimusRS. This is a manufacturer-described example, not a comparative ranking or a claim that Cartwright Fitness supplies the system. Obtain a current specification and quotation for your location and required configuration.
A report produced by a machine still needs professional interpretation. Do not assume that an automated score, equipment brand or supplier’s marketing claim establishes a person’s fitness for a particular job.
Relevant Cartwright Fitness equipment
We can help with equipment selection for professional fitness measurement. The products below support specific measurements; they are not sold here as a complete clinical FCE service.
Grip-strength measurement
The Takei Hand Grip Dynamometer has adjustable grip and analogue or digital options. Choose the model against your measurement requirements and use a consistent protocol. Our grip-testing guide explains the procedure considerations.
Chester Step testing
Where the selected assessment includes the Chester Step Test, the Chester Step Test Kit combines a step in the selected height with CST2 software and 100 test credits. A suitable heart-rate monitor is required separately. Check the product page for current options, availability and credit terms.
Use the applicable Chester protocol and step-height guidance. Chester Step testing estimates aerobic fitness; it does not measure lifting capacity or establish overall fitness for work. Practitioner training information is available separately.
Other measurements and software
Browse our professional testing equipment or ask about your equipment requirements. Include the protocol, measurements, number of testing sites and equipment you already own so we can confirm suitable options.
For software, request Cartwright Assess details. Tell us which assessments and reporting processes you need, and confirm current support for those requirements before choosing a setup.
Calibration, records and running costs
Ask how each instrument is checked, what reference equipment is required, who can perform the work and what happens if a check fails. There is no single maintenance or recalibration interval suitable for every instrument; use the applicable device instructions and service requirements.
Our calibration and verification guide explains the distinction between checking performance, calibration and adjustment. Keep instrument identification, checks, faults, corrective actions and the procedure used with the assessment record.
Compare the total requirements before accepting a quote:
- Hardware, attachments and any installation work.
- Initial training and time to establish consistent procedures.
- Software licences, updates, export options and support.
- Reference equipment, calibration, servicing and downtime.
- Consumables, cleaning, replacement parts and transport.
- Delivery charges and the precise items included.
Ask suppliers to confirm these items in writing. Use current quotations rather than unsourced price ranges or star ratings.
What to send with an equipment enquiry
A useful enquiry contains the intended protocol or task list, the measurements required, expected testing volume, locations, equipment already in use and any known software or reporting requirements. A budget range and target date help narrow the options.
Discuss your setup with Cartwright Fitness. We can confirm the equipment options we supply and identify questions that need to go to the protocol owner, manufacturer or clinical assessment provider.